DSE8005 SCADA Suite PC Software Manual ISSUE 5.1 DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual Document Number 057-128 Au
Installation 10 3.3.3 CONNECTION TO COMPANY INFRASTRUCTURE ETHERNET Requirements • DSE module with the ability to connect to Ethernet • Ethernet
Installation 11 3.3.4 CONNECTION TO THE INTERNET Requirements • Ethernet cable (see below) • Working Ethernet (company or home network) • Workin
Installation 12 3.3.5 FIREWALL CONFIGURATION FOR INTERNET ACCESS As modem/routers differ enormously in their configuration, it is not possible for
Operation – Graphical Setup 13 4 CONFIGURING THE SCADA SUITE To run the SCADA Suite Editor Software click the Windows start button or depending
Operation – Graphical Setup 14 To add devices to the system, ‘drag’ them from the side bar to the canvas. Example of an entire system : When addi
Operation – Graphical Setup 15 4.1 PROPERTIES The ‘properties’ section is used to setup the communications with the controller with a choice of RS2
4.2 SAVING FOR USE WITH Save the file to the Deep Sea Electronics PLC • DSEScadaSuite.xml Example (Where Username is replaced with your Windows logi
Operation - System 17 5 USING THE SCADA SUITE To run the SCADA Suite Software program click the Windows start button or depending upon your ver
Operation - System 18 5.1.1 CONFIG Clicking the CONFIG button on the System page allows configuration of the application options. This allows confi
Operation – Autostart Controller 19 5.2 AUTOSTART CONTROLLER NOTE:NOTE:NOTE:NOTE: Depending upon module type and configuration, certain pages
DSE8005 SCADA Suite PC Software Manual 2 DEEP SEA ELECTRONICS PLC Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 172
5.2.2 ENGINE Indicates that this is page 1 of 3 in this section.Press to move between the different parameters being reported from the
Operation – Autostart Controller 21 5.2.3 GENERATOR Indicates that this is page 1 of 9 in this section. Press to move between the different p
Operation – Autostart Controller 22 5.2.4 BUS Indicates that this is page 1 of 3 in this section. Press to move between the different pages i
Operation – Autostart Controller 23 5.2.5 ALARMS Alarm level Colour/Title graphic Warning Electrical trip Shutdown ECU code I
Operation – Autostart Controller 24 5.2.6 I/O 5.2.6.1 INPUTS Indicates that this is page 1 of 6 in this section. Press to move between the
Operation – Autostart Controller 25 5.2.6.2 OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not.
Operation – Autostart Controller 26 5.2.6.3 EXPASNION MODULES Indicates that this is page 4 of 6 in this section. Press to move between the d
Operation – Autostart Controller 27 5.2.6.4 REMOTE CONTROL NOTE:NOTE:NOTE:NOTE: Check the modules configuration before activating a remote con
Operation – Autostart Controller 28 5.2.6.5 VIRTUAL LEDS The function the virtual LED is configured for Shows if the virtual LED is active or
Operation – Autostart Controller 29 5.2.7 ABOUT Shows the PC Software and module firmware version numbers
DSE8005 SCADA Suite Software Manual 3 TABLE OF CONTENTS 1 DESCRIPTION ...
Operation – Automatic Mains Failure Controller 30 5.3 AUTOMATIC MAINS FAILURE CONTROLLER NOTE:NOTE:NOTE:NOTE: Depending upon module type and con
Operation 5.3.2 ENGINE Indicates that this is page 1 of 3 in this section.Press to move between the different parameters being reporte
Operation – Automatic Mains Failure Controller 32 5.3.3 GENERATOR Indicates that this is page 1 of 9 in this section. Press to move between t
Operation – Automatic Mains Failure Controller 33 5.3.4 UTILITY (MAINS) Indicates that this is page 1 of 3 in this section. Press to move betw
Operation – Automatic Mains Failure Controller 34 5.3.5 ALARMS Alarm level Colour/Title graphic Warning Electrical trip Shutdown
Operation – Automatic Mains Failure Controller 35 5.3.6 I/O 5.3.6.1 INPUTS Indicates that this is page 1 of 5 in this section. Press to mov
Operation – Automatic Mains Failure Controller 36 5.3.6.2 OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is a
Operation – Automatic Mains Failure Controller 37 5.3.6.3 EXPASNION MODULES Indicates that this is page 3 of 5 in this section. Press to move
Operation – Automatic Mains Failure Controller 38 5.3.6.4 REMOTE CONTROL NOTE:NOTE:NOTE:NOTE: Check the modules configuration before activatin
Operation – Automatic Mains Failure Controller 39 5.3.6.5 VIRTUAL LEDS The function the virtual LED is configured for Shows if the virtual LED
Installation DSE8005 SCADA Suite PC Software Manual ISSUE 5.1 1 DESCRIPTION This manual covers the operation of the DSE SCADA Suite software for D
Operation – Automatic Mains Failure Controller 40 5.3.7 ABOUT Shows the PC Software and module firmware version numbers
Operation – Mains Controller 41 5.4 MAINS CONTROLLER NOTE:NOTE:NOTE:NOTE: Depending upon module type and configuration, certain pages and values
Operation – Mains Controller 42 5.4.2 UTILITY (MAINS) Indicates that this is page 1 of 9 in this section. Press to move between the different p
Operation – Mains Controller 43 5.4.3 BUS Indicates that this is page 1 of 3 in this section. Press to move between the different pages includin
Operation – Mains Controller 44 5.4.4 ALARMS Alarm level Colour/Title graphic Warning Electrical trip Shutdown Indicates tha
Operation – Mains Controller 45 5.4.5 I/O 5.4.5.1 INPUTS Indicates that this is page 1 of 6 in this section. Press to move between the inputs,
Operation – Mains Controller 46 5.4.5.2 OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not. This
Operation – Mains Controller 47 5.4.5.3 EXPASNION MODULES Indicates that this is page 4 of 6 in this section. Press to move between the diffe
Operation – Mains Controller 48 5.4.5.4 REMOTE CONTROL NOTE:NOTE:NOTE:NOTE: Check the modules configuration before activating a remote cCheck
Operation – Mains Controller 49 5.4.5.5 VIRTUAL LEDS The function the virtual LED is configured for Shows if the virtual LED is active or not
Installation 5 3 HARDWARE INSTALLATION 3.1 RS232 RS232 is for short distance communication (max 15m) which can be used for single controller appli
Operation – Mains Controller 50 5.4.6 ABOUT Shows the PC Software and module firmware version numbers
Operation – Bus Tie Controller 51 5.5 BUS TIE CONTROLLER 5.5.1 HOME Indicates the current page selected. Click the buttons to change t
Operation – Bus Tie Controller 52 5.5.2 BUS Indicates that this is page 1 of 5 in this section. Press to move between the different pages in
Operation – Bus Tie Controller 53 5.5.3 ALARMS Alarm level Colour/Title graphic Warning Electrical trip Indicates that this is
Operation – Bus Tie Controller 54 5.5.4 I/O 5.5.4.1 INPUTS Indicates that this is page 1 of 6 in this section. Press to move between the in
Operation – Bus Tie Controller 55 5.5.4.2 OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not. Th
Operation – Bus Tie Controller 56 5.5.4.3 EXPASNION MODULES Indicates that this is page 3 of 3 in this section. Press to move between the dif
Operation – Bus Tie Controller 57 5.5.5 ABOUT Shows the PC Software and module firmware version numbers
58 This Page Intentionally Blank
Installation 6 3.2 RS485 RS485 is used for point-to-point cable connection of more than one device (maximum 32 devices) over a large distance (max
3.3 ETHERNET The DSE7400 and DSE8000 series modules are(local area networks) Terminal Description1 TX+ 2 TX- 3 RX+ 4 Do not connect5 Do not c
Installation 8 3.3.1 DIRECT PC CONNECTION Requirements • DSE module with the ability to connect to Ethernet • Crossover Ethernet cable (see Belo
Installation 9 3.3.2 CONNECTION TO BASIC ETHERNET Requirements • DSE module with the ability to connect to Ethernet • Ethernet cable (see below)